fire suppression system

Home » fire suppression system » Page 2
fire suppression system

(Showing 13 – 24 products of 24 products)

Show:
Featured
CNC Panel fire suppression systemcnc-machine-fire-suppression-system

CNC Panel fire suppression system

(0)
Highlights:
CNC Based Fire Protection are designed by Fire Engineering Technology to meet the most robust and demanding tandards in India and around the world. Our automatic fire suppression systems are independent of power supplies which ensures detection and suppression in any condition.
CNC Fire Suppression & Protection system are recognised by major insurance underwriters and supported by a comprehensive fire risk assessment before installation. Our CNC fire protection system is suitable to be fitted to all CNC machines including high precision machines and swiss.
The Reacton CNC machine fire suppression system uses our proprietary detection tubing, which once installed in the protected area will detect a fire inside the CNC Mills. Once the fire is detected, our automatic pneumatic value operates, causing the extinguishing agent to be released into the CNC Milling machines to extinguish the fire.
CNC detection system features :
Fully Vibration and  Corrosion Tested
Integrated Isolation Valve
Stainless Steel alloy 303 (UNS S30300)
Multi Port High Flow Discharge
Multi Cylinder & Agent On One Detection Circuit
Please get in touch with us to discuss a CNC machining fire suppression risk assessment and solution.
Featured
Container Handling Rack Fire Suppression SystemContainer Handling Rack Fire Suppression System2

Container Handling Rack Fire Suppression System

(0)
Highlights:

Installation of effective automatic fire detection and suppression systems on container handlers can help minimize equipment downtime, prevent loss of expensive equipment, and safeguard against serious injury.

Container Handling Rack Fire Suppression System

Areas to Protect in Container Handling Equipment

  • Engine Compartments

Failures in hydraulic hoses or fuel lines can cause fuel or hydraulic oil to leak or spray throughout the compartment. Once in contact with hot components in the engine, the fuel or oil can ignite – filling the whole compartment with fire.

  • Crane Electrical Panels

Overcurrent in panels within the crane’s electrical room can cause wiring and components to burn. A fire in an unprotected panel can destroy the panel and spread throughout the electrical room.

  • Crane Electrical Rooms

Electrical faults can cause wiring and components to burn, and lead to arc flash within the crane’s electrical room. In these cases, the spread of fire can be catastrophic, destroying the room and possibly the crane, leading to collapsing booms and beams.

Featured
ELECRICAL PANELS FIRE SUPPRESSION SYSTEMS

Electrical Panels Fire Suppression Systems

(0)
Highlights:
Studies show that a number of explosive fires can erupt from the general electrical panels present in practically every residential or commercial area. Regardless of the size of the electric panels, severe fire hazards can take place in them causing a lot of life and resource damage.
Since we believe in safeguarding you from fire hazards from all fronts, we also provide fire suppression system for electrical panels.
At Fire Engineering, your convenience and safety are our prime goals. To fulfil them, we design extremely proficient fire suppression systems for your electric panels which come ready for installation in your work unit.
Tube Based Gas Suppression System : One of the most prominent products/solutions at av safety solutions is the specially designed Tube-based Gas Suppression system, a revolutionary fire safety solution to keep safe what’s precious. The pneumatic mechanism triggers the valve of the extinguisher and sprays the extinguishing agent out of the tube directly onto the flame, dousing the fire instantaneously.

Unattended small short circuits are the main cause of most and major Fires. Fire in Server Racks or Electrical Panels are generally caused by a short circuits or small sparks but as they are not attended, they lead to serious hazards to life and property leading to personnel injuries, property damage further resulting in loss of productivity, money and precious time.

The following are the features of Tube Based System:

  • Simple self-activating system without human intervention
  • Linear Heat Detection – senses fire anywhere along the entire  length of the fire detection Tube
  • Extinguishes fire at an early stage
  • System activates automatically
  • Safe against malfunction
  • More reliable, as system does not rely on complex electronics or moving parts
  • System does not need external power supply for detection and extinguishing of fire
  • Simple construction leads to easy maintenance

System Configuration:

  • FET Fire Finder Tube for Detection
  • Fire Extinguisher Cylinder with Automatic Valve Assembly
  • Clean Agent Fire Fighting Gas
  • Pressure Switch
  • Audio Alarm
  • Control Panel

 

DLP- Direct Low-Pressure Clean Agent Systems are primarily a Pre-Engineered Automatic Fire detection and suppression System utilising various Low-pressure Clean agents i.e. HFC227ea, Novec1230/FK-5-1-12.

The Linear Pneumatic Fire Detection Tubing (LP-FDT) is installed and connected to DLP Valve and routed throughout the protected hazard area/enclosure. The primary function of Pneumatic Fire Detection Tube (under pressure) is to detect heat/fire and activate the valve for discharge of the agent by rupturing at the hottest point along its installed length on flame impingement. On rupture a nozzle is formed at the burst point.

The clean agent under pressure, in the cylinder then flows out through the burst point, distributing the clean
Direct Low Pressure DLP Clean Agent System Unit.

Featured
Foam Based Fire Protection SystemAutomatic foam fire suppression system

Foam Based Fire Protection System

(0)
Highlights:

Foam is the preferred fire suppression agent in scenarios involving the storage of combustible or flammable liquids in tanks or bulk storage facilities. It demonstrates remarkable effectiveness when applied to the surface of such liquids. Unlike water, which is denser and tends to sink, foam is lighter and rises to the top. This unique property allows it to form a protective blanket on the liquid’s surface, reducing vapor formation and impeding oxygen from reaching the combustible liquid. As a result, the foam effectively suppresses and controls the fire hazard.

Featured
FUME HOOD CABINET SUPPRESSION SYSTEMElectrical Panel fire suppression system

Fume Hood Cabinet Suppression System

(0)
Highlights:
Fume hoods square measure thought of as a perfect means of protective chemical laboratories from fireplace explosions. However, a fume hood on its own may not be decent. several reactive chemicals during a laboratory may act within the fume hood to make severe hazards.
In order to secure chemical laboratories, prescribed drugs, etc. from such things, we’ve come back up with a specialised fume hood cupboard fireplace suppression system which might defend the lives and resources of our shoppers.
FUME HOOD CABINATE FIRE SUPPRESSION SYSTEM: Fire Engineering Technology a reliable & service based company has 500+ reputed satisfied customers for Fire suppression system. 
A COMPLETE PRE-ENGINEERED SYSTEM

  • Designed to protect Fume Cabinets and Chemical storage enclosures
  • Everything you need together in one box
FULLY AUTOMATIC

  • Automatically detects and suppresses fire
  • No electricity required
FAST DETECTION

  • Installs directly INSIDE fume cabinets – closer to where a fire can start
PROVEN TECHNOLOGY

  • UL and FM-approved systems available
  • Already protecting thousands of installations worldwide
Featured
KITCHEN FIRE SUPPRESSION SYSTEMKITCHEN FIRE SUPPRESSION SYSTEM

Kitchen Fire Suppression System

(0)
Highlights:
Restaurant kitchens area unit significantly pre-disposed to fireside hazards. Despite the constant destruction of flames, the massive range of practical gas stoves will cause a fireplace to erupt. Such a scenario in your edifice wouldn’t solely impact your business adversely however additionally hurt your staff, resources and time. At  AV Safety Solutions, we’ve got in an elaborate way designed a room fireplace suppression system which will safeguard you against all such hazards.
Product potency
The system mechanically detects the presence of fireside while not the necessity for any human intervention.
Our system uses 3 strategies to discover the presence of fireside – liquified links, linear gas, and linear liquified links. Such a system ensures the fastest and most correct fireplace detection.
As presently as detected, the system straight off begins the method of fireside suppression to confirm minimum harm to life and resources.
We use a wet chemical for extinction the fireplace. Since this method is formed specifically for kitchens, the chemical used is one with an occasional pH scale and doesn’t corrode stainless-steel.
The system includes Associate in Nursing extinction tank that’s controlled and pre-filled to confirm immediate action and optimum safety.
The most distinctive quality of all {the fireplace|the hearth|the fireplace} Engineering fire suppression merchandise is that they’re created with utmost exactitude. we have a tendency to check them multiple times through multiple difficult tests. when we have a tendency to area unit certain that they perform well in dangerous things, we have a tendency to install them in your kitchens for your safety. that’s why once victimization our merchandise, you just don’t ought to worry concerning the standard.
Featured
Record Handling Rack Fire Suppression SystemRecord Handling Rack Fire Suppression System

Record Handling Rack Fire Suppression System

(0)
Highlights:

Records have an increased risk of fire- and smoke-related damage, more than many other materials. The nature of most archives and records often means that they consist of or have large amounts of very dry and old paper and books — items that are often highly flammable, as well as irreplaceable if a fire were to occur. Every archive or record repository, therefore, needs to take active steps to help prevent fires and to help reduce any potential damage to the building and its contents in the event of a fire.

Record Handling Rack Fire Suppression System

Types of Fire Protection Systems

Fire protection systems are categorized as active or passive depending on whether or not they perform an action to help extinguish the flames or alert people to the presence of the fire or whether their presence is enough to help block the spread of smoke and flame by itself.

Active Fire Protection Systems

Active fire protection systems help stop the spread of fire and smoke. By helping to contain the flames, they can help make it easier for active systems to extinguish them.

Passive Fire Protection Systems

Passive systems can help prevent damage to additional areas in the building and can make it safer and easier for occupants to exit.

Featured
Electrical Panel fire suppression systemServer Rack Fire Suppression System

Server Rack Fire Suppression System

(0)
Highlights:

Rack mount fire protection solutions are designed for installation into server racks and server cabinets to provide fast and effective fire detection and suppression and reduce the threat of fire to business continuity. When sizing a rack mounted fire suppression unit it is important to measure the physical space to be protected and ensure that the right size unit is selected and installed either as a single or multiple units.

Server Rack Fire Suppression System

Inert gas is a type of fire suppressant that safely extinguishes IT-related fires, while being safe for humans in the area and the environment. It is commonly used to protect smaller server rooms, particularly those where people are frequently. Data center fire suppression refers to various systems and solutions designed to stop a fire from spreading in a data center. You can typically find fire suppression systems aimed at different sections of a data center, such as those for the entire building, individual rooms and racks.

Featured
Vehicle Engine Fire Suppression SystemVehicle Engine Fire Suppression System

Vehicle Engine Fire Suppression System

(0)
Highlights:
 AV Safety Solutions offers a fully automatic, standalone fire protection system for vehicles, buses, and other engine and hydraulic system. We offer custom suppression systems to protect the vehicles, equipment, and vital assets.
Automatic vehicle suppression systems are designed with detection wires that are wrapped around the perimeter of the vehicle’s engine. When the insulation on one wire melts (reaching a temperature of 356? or higher), the melted wire touches the other wire and a message is sent to the control panel to dump the system and extinguish the fire
Manual systems on the other hand require the operator of the vehicle to push a button to initiate the suppression system.
Common causes of vehicle fires
There are several industries where vehicle fire suppression systems are used on heavy equipment. For example, landfills, underground mines, paper mills, railyards and power plants all have fire safety requirements for vehicles.
  • Abrasion against a high-pressure hydraulic line causes a pinhole and leaks atomized hydraulic fluid onto a hot manifold.
  • Combustible solids gather behind the hot exhaust manifold in the engine compartment of a trash truck.
  • A short occurs in one of the machine’s electrical cables, setting the cable insulation on fire.
  • Natural Gas or Hydrogen, highly flammable invisible fire hazards, ignite from the accidental discard of a cigarette butt.
  • Coal dust ignites from a metal spark.
  • A wiring harness near the battery shorts against the vehicle’s chassis, melts, and then ignites.
Featured
9-ltr-water-stored-pressure-type-fire-extinguisher-is-15683-2018-500x500fyrex-clean-agent-fe-36-4-kg-is-15683-stored-pressure-500x500

Water 9 Ltr IS: 15683 Stored Pressure

(0)
Highlights:

Product Specification

Capacity 9 litre
Extinguisher type Stored Pressure
Discharge Time 10-15 sec
Discharge Range 10 meter
Operating Temperature -5 DegreeC to +55 DegreeC
Fire Rating 2 A, 3 A
Fire Type A, B, C
Approvals ISO, ISI
Expelling Agent CO2
Brand SAFEX

Product Description

We are providing best quality products as per requirement and demand of buyers.
Featured
Water Mist Cylinder System

Water Mist Cylinder System

(0)
Highlights:

The Water Mist Fire Protection System can be provided in the form of self-contained Pressure Skid Modules (PSMs). The water capacity within these modules is determined through hydraulic calculations, considering factors such as the type and number of installed nozzles, as well as the desired operational duration of the system. To prevent corrosion and internal discoloration of water, high-pressure lined steel cylinders are utilized. For system pressurization, dry nitrogen gas is employed.

Water Mist Pump System – General Arrangement

CLOSED SYSTEM

Water Mist Pump System - General Arrangement

OPEN SYSTEM

Water Mist Pump System Components

Water Mist Cooling System

In hot and dry areas, our Water Mist Cooling Systems offer a straightforward, cost-effective, and attractive solution to reduce temperatures by 10-12 °C both outdoors and indoors. What sets our systems apart is that they achieve this cooling effect without causing wetness or excessive humidity.

Featured
Wind Turbine Fire Suppression SystemWind Turbine Fire Suppression Systems

Wind Turbine Fire Suppression System

(0)
Highlights:

Wind turbines catch fire because highly flammable materials such as hydraulic oil and plastics are in close proximity to machinery and electrical wires. These can ignite a fire if they overheat or are faulty. Lots of oxygen, in the form of high winds, can quickly fan a fire inside a turbine.

Wind Turbine Fire Suppression System

It is nearly impossible to put out a wind turbine fire using manual fire-fighting methods. The height of turbines, potential of the blade still rotating, and the remote locations many wind farms make them difficult, if not impossible, for local fire departments to battle. Combustible materials in the wind turbine are also risk factors. Composite materials are found in the blades, nacelle walls, and an estimated 235 gallons of lubricating oil and other highly combustible liquids that are held in the nacelle. These oils and liquids are used in the gearbox, yaw, hydraulic system, blade pitch change mechanism, oil pumps, mechanical brake, and oil-filled transformer. All that is needed is an ignition source to spark a fire.

Wind Turbine Fire Protection Options

Water-based

Carbon Dioxide (CO2)

Aerosol-based

Clean Agent

Scroll To Top
Close
Close

Shopping Cart

Close

Shopping cart is empty!

Continue Shopping