Kitchen Fire 6 Ltr IS: 15683 Stored Pressure
Key Features
- High quality Wet Chemical Agent.
- Unique gauge testing system (UGTS) mechanism
- Smooth & Polished Stainless Steel body Controlled discharge through Brass nickel plated Valve with squeeze operation.
- Easy to maintain, recharge & service.
- Latest CE marked.
- Tamper seal to detect any mishandling.
- Anti-corrosive Phosphate treatment of Cylinders.
- Manufactured of durable high quality materials.
- Large loop stainless Pull pin.
- More flexible EPDM hose.
- Lever lock for better handling.
- Bar Code labeling for better traceability.
- Discharge Nozzle is made up of Aluminum and Design allows a broad, dispersed discharge of agent that delivers a high volume low velocity delivery of wet chemical which doesn’t allow the burning Oil splash.
Kitchen Fire Suppression System
LIFE JACKET
Product Details:
| Color | Orange |
| Gender | Unisex |
| I Deal In | New Only |
| Country of Origin | Made in India |
| Size | Free Size |
| Brand | AXNOY |
| CODE | AXN-LFG |
A life jacket is a kind of personal floating device that is one of the vital safety gear essential for various water activities. Whether it’s rafting, kayaking or simply being on the water, a life jacket is a necessity. The offered life jackets play a crucial role in decreasing the risk of drowning. As the open sea is unpredictable even a diving expert can get conscious because of any unexpected hit. This is why life vests are a crucial part of every industry and operation which takes place on the water.
Mechanical Foam 9 Ltr IS: 15683 Stored Pressure
Product Specification
| Capacity | 9 litre |
| Extinguisher Type | Stored Pressure |
| Fire Rating | 3 A, 21 B |
| Fire Type | A, B |
| Cylinder Material | Stainless Steel (SS) |
| Brand | firex |
| Design | Wall mounted |
| Certifications | ISI, CE |
| Minimum Order Quantity | 1 |
Product Description
FEATURES
-
- Lightweight stainless steel cylinder
- Rugged epoxy coated finish
- UV resistant paint
- Resist corrosion, dents and punctures
- Chrome plated brass valve body
- Stainless steel handles and levers
- Stainless steel hose retaining clip
- Controlled on/off discharge
- Contains Tridol S 6% AFFF high performance concentrate for use on crude oil, petrol, diesel fuel and aviation kerosene fires
- Pressurised with standard air chuck
- Wall hanging bracket
- Service Maintenance tag fitted
- Approved to AS/NZS 1841.4
APPLICATIONS
-
- Suitable for A Class Fires – (paper, wood, textiles)
- Suitable for B Class Fires – (flammable liquid fires such as oils, petrols and solvents)
- Dangerous if used on energised electrical equipment
Medium Velocity Water Spray System (mvws) For Flammable Gas Storage Tanks
| Style | all |
| Surface Finishing | MV-A & MV-AS Natural Brass finish and Chrome Plated |
| Horizontal Storage Vessels | LPG Bullets,NH3 Storage tanks etc. |
| Vertical Storage Vessels | Benzene,Xylene,Toluene Tankage etc. |
| Spherical Storage Vessels | LPG bullets,Spheres etc. |
We are manufacturer and imprter , we provide the product,Medium Velocity Water Spray System (mvws) For Flammable Gas Storage Tanks.
Mulsifyre System Sprinkler Systems
Product Description
The sprinklers are connected to pipe work, usually filled with water, which is supplied either from the water mains or from a storage tank via a pump. When a sprinkler operates, the flow of water in the pipe work operates a flow switch which in turn operates an alarm system. The flow of water is small, usually less than 1/100th of the water used by the Fire and Rescue Service.
Sprinklers do not go off accidentally and are only triggered by real fires. They are also very reliable and only 1 sprinkler in 16,000,000 exhibits any form of manufacturing defect. Sprinklers save lives, buildings, stock, assets and jobs. They also help prevent carbon gases by reducing fires.
Nitrogen Injection & Oil Evacuation System
Why NIOES (NIFPS)
The NIOES (NIFPS) Transformer, found in power plants and substations, is known to be one of the most expensive pieces of equipment. It contains a significant amount of combustible substances, which can pose a fire hazard and lead to power failures and substantial economic losses. Therefore, safeguarding these transformers is of utmost importance.
Conventional systems such as the “High Velocity Water Spray System / CO2 Gas Flooding System” offer external protection by activating when a fire starts around the transformer or when the transformer has already experienced an explosion. In contrast, the “Nitrogen Injection Explosion Prevention & Fire Protection System” provides internal protection by preventing the transformer from exploding in the first place. Transformers are prone to explosions due to factors like overheating, overloading, winding short-circuits, or earth faults. The nitrogen injection system addresses these issues.
It’s important to note that the nitrogen injection system does not protect the transformer from external fires. Instead, it focuses on preventing explosions by injecting nitrogen inside the transformer body. As a result, the “Nitrogen Injection Explosion Prevention System” is not intended as a substitute for the HVWS/CO2 Flooding System. Instead, its installation is recommended as an additional measure alongside the HVWS/CO2 Flooding System to enhance overall transformer protection.
Characteristics of NIOES
State-of-art concept : Rapidly drain oil to prevent explosion and inject nitrogen to prevent and extinct fire.
Excellent performance : Utilizing fast valves to drain oil within seconds with the most advanced technique.
Fast response : Once a fault signal is detected from the Transformer. The oil is drained within second after detection in order to release pressure and to avoid explosion. The nitrogen gas is injected after 1 to 20 second in order to mix and cool down the oil, to reduce the concentration of flammable gases, to isolate oxygen gas, and to extinct fire.
Reliability : Utilizing the principle of logic signal to prevent any improper or unnecessary activity to the system and to provide a more flexible system.
High efficiency : Able to inject nitrogen gas continuously for more than 30 minutes to completely cool down the transformer oil as well as prevent and extinguish fire.
Reduce pollution : No Environmental pollution due to the characteristic of nitrogen gas. Extinct fire without water is an advantage to the lack of water area.
Feasibility : Easy to install and maintain for both new or existing transformers with reasonable investment in a minor price compare to other traditional transformer fire extinction systems, such as water spraying systems and CO2 spraying systems.
Functions : Explosion Prevention and Fire Extinguishing system can extinguish the fire immediately with the Nitrogen Gas injected into the Transformer Tank.
The Nitrogen can be injected continuously for 30 Minutes to stir and cool down the transformer oil, which also isolated the air from the tank.
Benefits of NIOES
When activated, the system swiftly extinguishes fires within seconds, ensuring rapid fire suppression. Moreover, it effectively prevents transformer explosions from occurring. Nitrogen gas, being inert, does not react with transformer oil, guaranteeing the integrity of the system. Additionally, it is completely non-toxic and non-hazardous, ensuring safety in its operation.
This system provides exceptional cooling capabilities to the transformer oil, aiding in maintaining optimal operating temperatures. It forms an insulating layer of a nitrogen (N2) blanket on the top surface of the oil, further enhancing its protective properties.
One of the advantages of this system is its lower installation and maintenance costs, making it a cost-effective solution. It is also environmentally friendly, aligning with sustainable practices. Furthermore, it is particularly suitable for areas facing water scarcity, making it an ideal choice in such locations.
For external fire protection, the option of the CNF Spray System is available, providing an additional layer of safety and protection, although its use is optional.
Scope of Application
Generator Power is unceasingly increasing with the development of technology, there are many transformer explosion happened due to ineffective of current breaker between the Generator and Power Transformer.
Our System’s USP
Auto Dialer Facility – a pre-recorded message will be sent to already registered phone numbers in the system in case of any system activation. (Max 3 numbers)
A mechanical interlocking has been provided to ensure that nitrogen injection will not take place into the transformer until the oil drain valve is open.
Nitrogen Injection Oil Evacuation Fire Protection System
| Type | Nitrogen Injection system |
| Capacity | 2 MVA to 500 MVA, 2 MVA To 500 MVA |
| Usage/Application | Industrial, Commercial and Residential |
| Fire Extinguisher Type | Nitrogen Injection Systems |
| Phase | Single Phase |
| Transformer Type | Power Transformer, Current Transformer, Potential Transformer, Distribution Transformer |
| Discharge Time | 30 Min. |
| Brand | Tri Parulex |
Nitrogen injection & evacuation system can be used to protect the transformers from fire & explosions
HOW A TRANSFORMER EXPLODE & GET FIRE
An Arc is generated due to any internal fault in the Transformer.
And a high energy flows through transformer.
Which lead to decomposition of insulation/oil at high temperature.
Top oil surface attains temperature higher than ignition point.
Huge thermal energy is generated thereby emitting combustible gases.
Pressure built-up resulting in tank rupture normally at top cover.
Hot oil when comes in contact with the oxygen catches fire.
why to use nitrogen injection system
On activation, the system extinguish the Fire within seconds.
It prevent the Transformer from explosion.
Nitrogen Gas is inert and does not react with transformer oil.
It is completely Non-hazardous
It provides best cooling effect to the oil inside the Transformer.
Forms insulating layer (Thermal) on top surface of the oil.
Easily available and in-expensive.
Environment friendly.c
Additional Information:
- Item Code: NIFPS
- Production Capacity: 30 Sets Monthly
- Delivery Time: 2-3 weeks
- Packaging Details: As per Standard
Plastic Hexagonal Base Traffic Cone Sand Fillable
Product Details:
| Brand | AXNOY |
| Material | Plastic |
| Model Name/Number | AXN-PVTC-HEXA-750 |
| Usage/Application | Road Safety/Traffic Control |
| Color | Orange/Red/Yellow/Green/Blue |
| Weight | 3.500kg |
| Height | 750 mm |
| Base | 400 mm dia round |
| Base frame | Rubber |
| Shape | Conical |
Our Company is highly instrumental in offering the best quality Plastic Traffic Cone to our valuable patrons. These cones are made using genuine quality rubber and other material. Also, this offered range is suitable on the road and many more fields. Furthermore, these products are designed as per the clients’ requirements, with the assistance of our team of experts.
Features:
- Impeccable designs
- Splendid look
- Long service life
Additional Information:
- Item Code: LSS-RTC-03
Pri-safety 9 Ltr Mechanical Foam Fire Extinguisher
| Capacity | 9 litre |
| Fire Type | A, B |
| Brand | Pri safety |
| Certifications | ISI, CE |
PRI-SAFETY 9 LTR MECHANICAL FOAM FIRE EXTINGUISHER
Pri-safety ABC Ceiling Mounted 5 Kg (Map 90)
| Capacity | 4kg |
| Fire Type | B, C, A |
| Brand | PRI Safety |
| Certifications | CE, ISI |
PRI-SAFETY ABC MAP CEILING MOUNTED 5 KG (MAP 90)
PRI-SAFETY ABC MAP 50 4 KG
| Capacity | 2kg |
| Extinguisher type | Stored Pressure |
| Extinguishing Medium | Dry Powder IS 4308 /14069 |
| Fire Type | B, C, A |
| Brand | PRI Safety |
| Design | Wall mounted |
| Certifications | CE, ISI |
With our vast experience & knowledge in this field, we are engaged in providing a quality-assured range of Dry Powder Fire Extinguisher.
Features:
- Use upright pull out pin
- Aim at base of fire
- Squeeze levers and sweep side to side